Act now and download your Cisco 200-601 test today! Do not waste time for the worthless Cisco 200-601 tutorials. Download Abreast of the times Cisco Managing Industrial Networking for Manufacturing with Cisco Technologies exam with real questions and answers and begin to learn Cisco 200-601 with a classic professional.
Question 1
Given a ring topology, which loop prevention mechanism provides the fastest reconvergence time after a link failure?
Question 2
A ProfiNET management system operator is unable to see diagnostic information for a Cisco Industrial Ethernet switch that has been added to a SIMATIC management station. Based on the provided CLI output, which statement is correct?
switch# show profinet status State : Enabled
Vlan : 201
Id : IE2000-Switch Connected : Yes ReductRatio : 128
GSD version : Mis-match
switch# show profinet status State : Enabled
Vlan : 201
Id : IE2000-Switch Connected : Yes ReductRatio : 128
GSD version : Mis-match
Question 3
Exhibit:
Refer to the exhibit. Host 3 on Network A is sending data to Host 8 on Network B. Which address is the default gateway of Host 3?
Refer to the exhibit. Host 3 on Network A is sending data to Host 8 on Network B. Which address is the default gateway of Host 3?
Question 4
What security component can be deployed to increase the defense in depth and specifically can be positioned against 'man-in-the-middle' attack?
Question 5
Which of the following correctly pairs the dotted decimal subnet mask with the correct number of binary bits that represent the subnet mask?
Question 6
What percentage of an I/O connection would you set the RPI in order to ensure the application has the most current data?
Question 7
Which configuration enables an Industrial Ethernet switch to participate in PTP clock selection and sets the priority value that would break the tie between switches with matching default criteria to 50?
Question 8
Which option best describes the ProfiNET Discovery and Configuration Protocol (DCP)?
Question 9
To ensure ProfiNET Layer 2 Class-of-Service markings from ProfiNET devices are trusted by the switch, which command must be entered on the interface attached to the device?
Question 10
It is common to use Resilient Ethernet Protocol (REP) on the manufacturing floor as a resiliency protocol, as opposed to the Enterprise where it is not generally deployed. What are two reasons why REP is more suitable for the plant floor? (Choose two)
Question 11
Refer to the exhibit.
NAT has been configured on the router 'GW' and the IP addresses of router 'GW' have been configured properly. Users of PC1 and PC2 are able to ping the IP address 198.51.100.1 but are unable to reach any other IP addresses on the Internet. The ISP confirmed that their configuration is correct. Which option would likely correct the problem?
NAT has been configured on the router 'GW' and the IP addresses of router 'GW' have been configured properly. Users of PC1 and PC2 are able to ping the IP address 198.51.100.1 but are unable to reach any other IP addresses on the Internet. The ISP confirmed that their configuration is correct. Which option would likely correct the problem?
Question 12
How are I/O timeout and Safety I/O timeout calculated?
Question 13
Which two are possible solutions to control which devices can communicate between industrial zones? (Choose two)
Question 14
When troubleshooting a high packet loss condition in the network, the inspection area has an assessed M.I.C.E. value of M=1, I=1, C=3 and E=1. Which condition could be suspect?
Question 15
Refer to the exhibit.
Which values are correct for AP 2 to allow for efficient roaming?
Which values are correct for AP 2 to allow for efficient roaming?
Question 16
Refer to the exhibit.
Which two parameters can be used to diagnose an overloaded system? (Choose two)
Which two parameters can be used to diagnose an overloaded system? (Choose two)
Question 17
Refer to the exhibit.
All of the vlans listed in the routing table below are trunked using 802.1q and are active on all switches. PLC1, PLC2, and PLC3 each has IP address 192.168.0.1/24 and are connected to ports configured for vlan 50. L2SW1, L2SW2, and L2SW3 are not using vlan trunking for vlan 50.
L3SW1 has following routing table:
10.0.0.0/8 is variably subnetted, 12 subnets, 2 masks C 10.3.138.0/23 is directly connected, Vlan307
C 10.3.136.0/23 is directly connected, Vlan306 C 10.15.153.0/24 is directly connected, Vlan398 C 10.3.142.0/23 is directly connected, Vlan309 C 10.3.140.0/23 is directly connected, Vlan308 C 10.3.186.0/23 is directly connected, Vlan293 C 10.15.154.0/24 is directly connected, Vlan399 C 10.3.184.0/23 is directly connected, Vlan292 C 10.3.190.0/23 is directly connected, Vlan295 C 10.3.188.0/23 is directly connected, Vlan294
C 10.3.182.0/23 is directly connected, Vlan291 C 10.3.180.0/23 is directly connected, Vlan290
PLC1, PLC2, and PLC3 cannot be reconfigured. What can be done to be able to simultaneously communicate with PLC1, PLC2, and PLC3?
All of the vlans listed in the routing table below are trunked using 802.1q and are active on all switches. PLC1, PLC2, and PLC3 each has IP address 192.168.0.1/24 and are connected to ports configured for vlan 50. L2SW1, L2SW2, and L2SW3 are not using vlan trunking for vlan 50.
L3SW1 has following routing table:
10.0.0.0/8 is variably subnetted, 12 subnets, 2 masks C 10.3.138.0/23 is directly connected, Vlan307
C 10.3.136.0/23 is directly connected, Vlan306 C 10.15.153.0/24 is directly connected, Vlan398 C 10.3.142.0/23 is directly connected, Vlan309 C 10.3.140.0/23 is directly connected, Vlan308 C 10.3.186.0/23 is directly connected, Vlan293 C 10.15.154.0/24 is directly connected, Vlan399 C 10.3.184.0/23 is directly connected, Vlan292 C 10.3.190.0/23 is directly connected, Vlan295 C 10.3.188.0/23 is directly connected, Vlan294
C 10.3.182.0/23 is directly connected, Vlan291 C 10.3.180.0/23 is directly connected, Vlan290
PLC1, PLC2, and PLC3 cannot be reconfigured. What can be done to be able to simultaneously communicate with PLC1, PLC2, and PLC3?
Question 18
A shutdown in the cookie cutter machine was traced to a broken network cable. What are two reasons that explain why using DLR is an appropriate choice for network resiliency? (Choose two)
Question 19
A small manufacturing company has a Class C network address on the plant floor and needs to create five subnets, each accommodating 25 endpoints. Which subnet mask needs to be configured?
Question 20
Which CLI command will display IGMP snooping information in a Cisco IE2000 or Stratix 5700 switch?
Question 21
Which in-depth approach is used when deploying defense in an industrial zone?
Question 22
Refer to the exhibit.
CIP Implicit messages from I/O#1 are being marked IP DSCP 47 by the endpoint and this
marking is trusted by L2SW4. L2SW4 is configured to map DSCP 47 to output queue 1 threshold 1. You have received feedback that some of these messages are not being received. Executing the show mls interface GigabitEthernet statistics command on L2SW4 results in:
L2SW4# show mls interface GigabitEthernet 1/1 statistics
CIP Implicit messages from I/O#1 are being marked IP DSCP 47 by the endpoint and this
marking is trusted by L2SW4. L2SW4 is configured to map DSCP 47 to output queue 1 threshold 1. You have received feedback that some of these messages are not being received. Executing the show mls interface GigabitEthernet statistics command on L2SW4 results in:
L2SW4# show mls interface GigabitEthernet 1/1 statistics